Zhengzhou Airport Station
The Zhengzhou Airport Station project uses fireproof glass non-load-bearing partition wall.
Key words:
Zhengzhou Airport Station
Classification:
Product Centre
Fireproof glass non-load-bearing partition wall
Hotline:
Product introduction
The new "Building design fire protection Regulations" GB50016-2014 stipulates: "The connected space with the surrounding should be separated by fire prevention: when the fireproof partition wall is used, the fire resistance limit should not be less than 1.00h; When fireproof glass partitions are used, their fire insulation and fire integrity should not be less than 1.00h." Our large panel fire glass non-load-bearing partition wall A1.00 made by Fupu fire glass has passed the test and review of CCCF-CPRZ-18:2019 "Implementation Rules for Fire Protection Product Certification Fire Protection Products Building Refractory Component Products" and "General Technical Conditions for Fire resistant Glass non-load-bearing partition wall GA97-1995". Obtained the nationally recognized fire certification, the maximum size is 3200mmX4300mm, the maximum size of a single glass is 1500mmX4200mm. Landmark project case: Tianjin Lujiazui Financial Center CBD minus one floor, first floor, second floor 2800 square meters A1.00 fire insulation partition wall.
1. In a certain time, the glass together with the frame can meet the fire stability, integrity and heat insulation;
2. Has the special function of fire prevention, smoke insulation and high temperature blocking;
3. High-grade products, simple, good permeability;
4. A total of 4 products of Hengbao Company have obtained the national fire protection certification nationwide, of which 3200mmX4300mm large layout partition wall is the first product in the country, more to meet the needs of high-end customers;
5. Choose heat-insulating fireproof glass without adding automatic water spraying system.
Hengbao fireproof glass system products and precision/steel products have: green, environmental protection, fire prevention, heat, energy saving, low carbon and other characteristics, can be widely used in all kinds of industrial and civil buildings, including but not limited to the following locations will be used:
1. Airport projects: airport exterior curtain wall with fire-proof glass requirements, upper and lower curtain walls of airport shops, finger corridor passageway, airport fire division, etc.;
2. High-speed rail and transportation hubs: high-speed rail station outbound transfer hall, urban corridor and subway connection, sunken square, lighting roof and platform, etc.
Application scenario