Hongrongyuan One city center
Hongrongyuan One City Center project is the use of fireproof glass floor, lighting roof system.
Key words:
Hongrongyuan One city center
Classification:
Product Centre
Fire protection floor/light roof system
Hotline:
产品介绍
Fireproof glass floor and daylighting roof system is developed by Hengbao Company in accordance with the "Code for Fire Protection of Building Design". It is used for fireproof floor and fireproof daylighting roof, and meets the requirements of the new fire protection code. It is a horizontal fireproof glass component system with fire integrity, fire insulation and bearing capacity. The system includes a fire prevention system composed of fire-resistant supporting frame, load-bearing fire-insulating glass and fire-insulating sealing material, which can not only meet the lighting, but also meet the functions of fire prevention, heat insulation and load-bearing when a fire occurs. It solves many problems that glass floor and lighting roof are not fireproof. It is generally used in shopping malls, hotels, hospitals, shopping centers, public centers, stations, airports, high-speed railways, schools and other places to replace non-fireproof platforms and lighting Wells.
Application example

Fireproof glass floor
1. Fire insulation 60 minutes, 90 minutes, 120 minutes, the floor bearing more than 500kg per square meter, to meet the load-bearing design requirements of cement floor, to solve many glass floor, lighting roof is not fireproof problems;
2. As flexible as other fixed glass floor options, but carefully designed to comply with fire regulations;
3. Advanced technology for sound insulation, fire prevention, heat insulation, practical and reliable;
4. Elegant and luxurious design, as well as a perfect aesthetic design, even if there is a fire nearby, it is easy to walk around; 5. If there is a fire, the fire platform and lighting well can last 16 hours without collapsing.
☑Test of load bearing fire floor and lighting ceiling glass system
☑Fire resistance and load bearing tests according to European standard BS EN1365-2:2000 and British standard BS 476:Part 21:1987
☑ GB/T 9978.1-2008 "Fire resistance test methods for building components - Part 1: General requirements"
☑GB/T 9978.5-2008 "Fire resistance test methods for building elements - Part 5: Special requirements for load-bearing horizontal dividers"
Tel: 86-18948313962 E-mail:18948313962@139.com
Add: 8th Floor, Tangwei Stock Business Building, Tangwei Community, Fuhai Street, Bao 'an District, Shenzhen
Links:Fireproof Glass | Fireproof Window | Fireproof Window | Glass Fireproof Door | Fireproof Floor | Lighting Roof System | Fireproof Glass Component | Fireproof Glass Non-load-bearing Wall | Fireproof Glass Wall | Refined Steel Profile | Ming Frame Door Hidden Frame Door
Copyright©2024 All rights reserved of Shenzhen Hengbao Glass System Fire Protection Technology Co., Ltd.